Voltage stabilizer Eleks Hertz U 36-1/32 v3.0
The features of this stabilizer include an informative LCD screen, event memory, the highest stabilization accuracy, plotting voltage and load graphs, a three-language interface, the presence of electronic transit (bypass), and silent operation due to the use of triacs (thyristors) as power keys.
If it is necessary to obtain a voltage different from 220 V in Hertz at the stabilizer output, there is a function for adjusting this value in the range of 200-230 V.
The Hertz stabilizer has the ability to manually adjust the lower shutdown threshold (60-135 V). This feature is useful for loads with high inrush currents, which can cause a significant voltage drop and emergency shutdown of the stabilizer upon startup. When this option is activated, the stabilizer will start any motor or pump within a minute, even if the voltage drops to 60V in the network.
It is recommended to install and operate the GERZ U 36-1/32 v3.0 stabilizer in dry and heated rooms. It is recommended to wall-mount it vertically (with the fans facing up), leaving 10-15 cm of space above and below for cooling. Connection is made to existing wiring via a terminal block.
Артикул: LP16283
Delivery
Self-pickup
Exchange/return of goods within 14 days
Official warranty from
manufacturer
Cash, non-cash (including VAT).
PrivatBank, Oschadbank
| Key type | triac |
| Operating current, A | 32 |
| Rated power, VA/W | 7000/7000 |
| Number of stabilization stages | 36 |
| Stabilizer efficiency not less than, % | 98 |
| Power consumption at idle no more than, W | 35 |
| Rated output voltage, V | 220 |
| Minimum operating input voltage, V | 100 |
| Maximum operating input voltage, V | 280 |
| Output voltage adjustment, V | 200-230 |
| Lower shutdown threshold adjustment, V | 60-135 |
| Stabilization accuracy, % | 1.5 |
| Response time to input voltage change, ms | 20 |
| Power supply frequency, Hz | 45-65 |
| Input current and full | yes |
| Short-circuit and overload current limitation | input circuit breaker with B-characteristic of electromagnetic protection |
| Electronic Bypass | yes |
| Network and stabilizer status analyzer | yes |
| Duplicate overvoltage protection | yes |
| Microcontroller control | yes |
| Input choke | yes |
| Output choke | yes |
| Protection against overheating | yes |
| Minimum cross-section of cable cores for connection, mm² | 6 |
| Maximum cross-section of cable cores for connection, mm² | 30 |
| Forced cooling | two-speed fan |
| Length, mm | 280 |
| Width, mm | 165 |
| Height, mm | 475 |
| Warranty, months | 36 |
| Weight, kg | 21 |
| Volume, cubic meters | 0.021945 |