Voltage stabilizer Eleks Hybrid U 9-1/16 v2.0
The single-phase voltage stabilizer Hybrid U 9-1/16 v2.0 is designed for operation in very unstable electrical networks with significant voltage fluctuations from 135 to 315 V (145-300 V for low-power products). In this range, the device is guaranteed to produce an output voltage within 220±7.5%, which is ensured by using 9 stabilization stages.
The Hybrid range of power models is available in 5.5, 7, 9 kW versions, which corresponds to an operating current of 25, 32, 40 A, respectively, as well as low-power versions of 2.2 and 3.5 kW with an operating current of 10 and 16 A.
This stabilizer can operate with "green" power supply systems, and the Hybrid U 9-1/16 v2.0 has an electronic transit function (bypass), which distinguishes it from other models.
It is recommended to install and operate the Hybrid stabilizer in dry and heated rooms. Wall-mounted installation is recommended in a vertical position (with the fans facing up), leaving 10-15 cm at the top and bottom for cooling. Connection is made to existing wiring via a terminal block for units from 5.5 to 9 kW and via a built-in cord with a plug and socket on the stabilizer body for 2.2 and 3.5 kW models.
Артикул: LP16258
Delivery
Self-pickup
Exchange/return of goods within 14 days
Official warranty from
manufacturer
Cash, non-cash (including VAT).
PrivatBank, Oschadbank
| Key type | triac, duplicated by an electromagnetic relay |
| Operating current, A | 16 |
| Rated power, VA/W | 3500/3500 |
| Number of stabilization stages | 9 |
| Stabilizer efficiency not less than, % | 98 |
| Power consumption at idle no more than, W | 15 |
| Rated output voltage, V | 220 |
| Minimum working input voltage, V | 130 |
| Maximum working input voltage, V | 310 |
| Output voltage adjustment, V | no |
| Lower shutdown threshold adjustment, V | no |
| Stabilization accuracy, % | 7.5 |
| Response time to input voltage change, ms | 100 |
| Power supply frequency, Hz | 45-65 |
| Input current and apparent power measurement | yes |
| Short-circuit current limitation and Overload | Input circuit breaker with B-characteristic electromagnetic protection |
| Electronic Bypass | no |
| Network and stabilizer status analyzer | yes |
| Duplicate overvoltage protection | yes |
| Microcontroller control | yes |
| Input choke | no |
| Output choke | no |
| Overheat protection | yes |
| Forced cooling | two-speed Fan |
| Length, mm | 225 |
| Width, mm | 145 |
| Height, mm | 380 |
| Warranty, months | 24 |
| Weight, kg | 13.5 |
| Volume, cubic meters | 0.012398 |