Residual current circuit breaker 3x(1P+N) 6kA C-10A 30mA type QuickConnect, Hager ADZ360DResidual current circuit breaker 3x(1P+N) 6kA C-10A 30mA type QuickConnect, Hager ADZ360D

Residual current circuit breaker 3x(1P+N) 6kA C-10A 30mA type QuickConnect, Hager ADZ360D

The 3x (1P+N) 6kA C-10A 30mA QuickConnect Hager ADZ360D residual-current circuit breaker is capable of supplying power to lines with a capacity of up to 6.6 kW. The device features a C-type tripping curve and a maximum short-circuit current of 6 kA, recommended for household networks. The residual-current protection module is triggered by an AC or DC pulsating leakage current of 30 mA. This protects people from electric shock when in contact with live parts.
Manufacturer HAGER

Артикул:  ADZ360D

In stock
Buy in 1 click
5638,25 грн.
При заказе от 5 штук:
2210,32 грн.

                                                                              Delivery

Self-pickup

Product delivery point

By courier in Kyiv - by arrangement.cool
<div style=
In Ukraine - according to the carrier's rates center;">(Free delivery when ordering for
from 3000 UAH. for some product groups)
                                                                           Guarantee

Exchange/return of goods within 14 days

Official warranty from
manufacturer

                                                                                              Payment

Cash, non-cash (including VAT).

PrivatBank, Oschadbank


Number of protected poles: 3
Number of poles: 4 P
Polar system: 3x 1P + N
With disconnected pole N: yes
Trip: C
Safety trip indicator: yes
Rated frequency: 50 Hz
Rated short-circuit making capacity Icn: 6 kA
Power source type: AC
Rated voltage (AC): 230 V0 0 0 />Dielectric frequency value of voltage: 2 kV
Rated impulse withstand voltage 4000 V
Power loss per pole for rated current: 2.3 W
Total power loss for rated current: 7.7 W
Protection from case (number of cycles): 2000
Mechanical strength (number of cycles): 2000
Product depth: 70 mm
Product height: 86 mm
Product width: 71 mm
Tightening torque: 2 Nm
Dismantling of modular chambers: no
Adapted for flush mounting: yes
Capacity of the output terminal of the flexible hose (cable): 1/10 mm²
Capacity of the input socket for flexible cable: 1/4 mm²
Power output clamp />Capacity of the input socket for rigid wire: 1/4 mm²
Length of the guide (m) used for the heat test according to the product standard: 1 m
Cross-section of the guide (mm²) used for Thermal test according to product standard: /1>5² connection: yes
Protection class: IP20
Residual current source type: A
Residual current device type: A
Energy class I²t.: 3
Storage temperature: from -25 to 80°C

Add comment