Automatic motor protection switch PKZM0-6.3A 150kA EATON
Артикул: 72738
Delivery
Self-pickup
Exchange/return of goods within 14 days
Official warranty from
manufacturer
Cash, non-cash (including VAT).
PrivatBank, Oschadbank
Thermal release setting range: 4.0 - 6.3 A
Electromagnetic release setting: 88.2 A
Rated operational voltage Ue: up to 690 V AC
Rated insulation voltage Ui: 690 V
Rated impulse withstand voltage Uimp: 6 kV
Rated short-circuit breaking capacity Icu at 230 V AC: 150 kA
Rated short-circuit breaking capacity Icu at 400 V AC: 150 kA
Rated short-circuit breaking capacity Icu at 440 V AC: 150 kA
Rated short-circuit breaking capacity Icu at 500 V AC: 150 kA
Rated short-circuit breaking capacity Icu at 690 V AC: 50 kA
Rated service short-circuit breaking capacity Ics at 230 V AC: 150 kA
Rated service short-circuit breaking capacity Ics at 400 V AC: 150 kA
Rated service short-circuit breaking capacity Ics at 440 V AC: 150 kA
Rated service short-circuit breaking capacity Ics at 500 V AC: 150 kA
Rated service short-circuit breaking capacity Ics at 690 V AC: 50 kA
Rated frequency: 50/60 Hz
Number of poles: 3
Trip type: Thermal-magnetic
Utilization category: AC-3
Degree of protection (IEC/EN 60529) of terminals: IP20
Degree of protection (IEC/EN 60529) of housing: IP00
Mechanical durability: 100,000 cycles
Electrical durability at 400V AC, AC-3: 100,000 cycles
Ambient temperature during operation: -25 - +55 °C
Ambient temperature during storage: -40 - +80 °C
Altitude above sea level (without derating): up to 2000 m
Altitude above sea level (with derating): up to 4000 m
Connection type: Screw terminals
Cross-section of connected rigid conductor: 1 x (1 - 6) mm², 2 x (1 - 2.5) mm²
Connectable cross-section of flexible conductor with ferrule: 1 x (1 - 6) mm², 2 x (1 - 2.5) mm²
Tightening torque of terminals: 1.7 Nm
Dissipated power per pole at Ie: 2.51 W
Mounting method: DIN rail mounting (EN 60715) / Screw mounting
Width: 45 mm
Height: 93 mm
Depth: 76 mm
Weight: 0.25 kg
Relevant standards: IEC/EN 60947-1; IEC/EN 60947-2; IEC/EN 60947-4-1; UL 60947-4-1; CSA C22.2 No. 60947-4-1